Two numbers that answer two questions
Licensed capacity answers a safety question: how many people can be in this space and get out of it in time if something happens. It knows nothing about tables, menus or waiters. Operational capacity answers a question of the trade: how many people can I seat, serve and look after properly with this set-up.
The problem appears when one is used to answer the other's question. Someone who gives the licence number over the phone to a client who wants a seated dinner is promising double what can be served. And someone who sets up a cocktail thinking only of comfort can go over the authorised maximum without noticing.
This article explains where each figure comes from and how to live with both. It is not legal advice: the authorised capacity of a specific venue is the one in its licence, and any doubt about it is settled with the town council and a competent technician.
Where the licensed capacity comes from
In Spain, the technical starting point is the Basic Document on Fire Safety (DB-SI) of the Technical Building Code. Its section SI 3, on the evacuation of occupants, establishes that occupancy is calculated by applying to the usable area of each zone a density, in square metres per person, taken from its table 2.1. The table above gives the public assembly ("Pública Concurrencia") rows that most affect an event room.
For a hotel or conference room, the row that applies is that of multi-purpose rooms: 1 m² per person. For a seated public area in a restaurant, 1.5 m². For seated spectators with no seats defined in the project, 0.5 m². Which row corresponds to each room is not decided by whoever operates it: it is determined by the technician who writes the project and validated by the authority that grants the licence.
That number of people has to be able to evacuate, so the project checks that there are enough exits, of the necessary width and at the maximum permitted distance. If the exits do not cope with the occupancy that would come out by area, either the exits are enlarged or the occupancy is limited. The DB-SI itself warns that the densities apply unless a higher occupancy is foreseeable or another legal provision requires a lower one.
On top of this come the regional rules on public entertainment and leisure activities and municipal bylaws, which may set their own criteria. And there are rooms with licences older than the Technical Building Code, calculated with the rules of their day. For all these reasons, the licensed capacity of a room is not deduced from a table: it is read from the licence.
Where yours is written down
The authorised capacity appears in the activity or opening licence, or in the document that serves in its place depending on the municipality, and in the technical project that accompanies it. In many regions it is also compulsory to have a sign with the maximum capacity in view of the public; check the rules in yours.
It is worth reading the whole entry and not just the figure. The licence can give a capacity per room or one for the entire establishment, and can describe the spaces it refers to. A room, its terrace and a garden where a marquee is put up are not necessarily the same space for the purposes of the licence.
If the figure does not appear, or nobody at the venue knows where the one in use came from, it is time to ask the town council for a copy of the licence and have a technician review it. It is a one-off task that avoids selling for years with a number nobody can justify.
Where the operational capacity comes from
From the set-up, and only from it. A 180 cm round table with ten diners, their chairs and a 1.50 m service aisle takes about 17.5 m²: 1.75 m² per person. Before placing tables you have to set aside the head table, the dance floor, the bars and the aisles to the exits, which in a banquet with dancing usually take between a quarter and a third of the room.
The result depends on the table chosen, the aisle the service needs and the shape of the room, and changes with each set-up: it is not the same for a gala dinner as for cabaret or theatre style. The step-by-step calculation has its own guide; here it is enough to know that operational capacity is not an attribute of the room, but of a plan.
A 20 × 15 m room and its three capacities
A room of 300 m² usable in a hotel, no columns. Suppose its project calculated the occupancy as a multi-purpose room, at 1 m² per person, and that the exits were sized for it: authorised capacity, 300 people.
As a banquet, with 215 m² of table area and 180 cm rounds, 12 to 14 tables fit: 120 – 140 diners. That is between 40 and 47% of the authorised capacity. If that same room were calculated as a seated public area of a restaurant, at 1.5 m² per person, its capacity would be 200, and the banquet would be between 60 and 70%. The ratio between the two numbers is not a constant of the sector: it depends on the density with which the licence was calculated.
In theatre style, with a stage and three aisles, 13 rows of 24 chairs fit: 312 seats. Here the set-up exceeds the licence. Even though the chairs fit, the maximum is 300 people, and a row or half a row has to be removed.
At a cocktail, the room comfortably takes around one person per square metre, which is exactly the authorised capacity. With 300 guests, any additional person exceeds it.
The three capacities of this room are therefore 120 – 140 as a banquet, 300 in theatre style (and not 312) and 300 at a cocktail. Only the first is decided by the set-up. In the other two, the licence rules.
When the licensed capacity becomes the real limit
At a seated banquet it is hard to get close to the authorised maximum, because the tables take up a lot of space. The risk lies at other moments of the same event, and those are worth checking with the licence number in front of you.
- The welcome cocktail in a room or space smaller than the banquet room. The same 180 guests who fit seated in the room may not fit standing in the cloister where the drinks are served, if that space has its own capacity.
- Guests who join for the open bar. A wedding of 140 diners that is joined by 80 people after dinner is an event of 220.
- Theatre-style set-ups, where physically more chairs fit than the licence allows.
- Events that use two spaces. The DB-SI asks you to take into account whether the areas are occupied at the same time or alternately: a garden and a room that are never full at the same time are not added together, but two rooms open at once are.
- Staff. Waiters, kitchen, musicians, photographers and technicians are also occupants of the building. Whether your licence's capacity refers only to the public or to all occupants depends on how it is worded and on the rules that were applied to it; it is a question for the technician, and worth having answered.
How to state the capacity in an offer and in a contract
The number committed in writing is the operational one, and it has to come with the set-up it comes from. A method that avoids almost all later arguments:
- Draw the offered set-up on the scale plan of the room, with the exits and their aisles kept clear before placing tables.
- Count the places that come out of that plan. That is the capacity of the offer.
- Check that the sum of guests, and of staff if your licence includes them, stays below the authorised capacity at every moment of the event, not just at dinner.
- Write the figure with its condition: "up to 130 diners at round tables of 10, with a head table and a dance floor, as per the attached plan". Without the second half of the sentence, the number survives any change of set-up and stops being true.
- Attach the dated plan and keep it with the file. If the client later asks for more guests or changes the table, the plan is redone and a new number is given.
- Keep the licence figure to hand for the reverse question: when the client wants a cocktail or a standing party, the maximum you can offer is that one, however much more the room seems to take.
What is checked in an inspection
An inspection does not measure the distance between tables or judge whether service is comfortable. As far as matters here, it checks that there are no more people than authorised and that the means of evacuation are as the project says: exits that are usable and signposted, and routes to them without obstacles.
A practical consequence follows. Being well below the authorised capacity does not fix a blocked exit: a table, a bar or a photocall in front of an emergency door is a breach with 100 guests just as with 300. That is why the set-up plan has to begin with the exits. In MisePlan, doors marked as an emergency exit reserve a clear aisle in front and the plan warns if a table intrudes on it; it does not replace the room's project, but it avoids the most frequent mistake.
Insurance is the other reason to keep the numbers in order. Public liability policies are usually taken out by declaring the activity and the capacity, and the prudent thing is for the declared capacity, the licence's and the one you sell to be consistent with each other. If you are not sure, ask your broker before the season, not after a claim.
Terraces, gardens and marquees
The licence capacity refers to the spaces the licence describes. A garden, a threshing floor or an esplanade where a marquee is put up for a wedding may not be included, or may be included with different conditions, and a marquee is a temporary installation that usually needs its own technical documentation.
The DB-SI treats open-air areas differently when it comes to sizing their routes and exits, but that does not mean an outdoor space has no capacity. Before selling a set-up in a space that is not the usual room, it is worth confirming with the town council and the technician what can be done there and for how many people.